Beisler 739-23-1 Manual User Manual
Page 24
aintenance tasks
Description
Operating
to be carried out
hours
Waste container
Extractor system
Empty waste container 5.
Empty dust bag 4.
8
Pneumatic system
- Inspect water level at pressure
regulator.
- Clean filter cartridge 6.
- Inspect system for leakage
The water level may not reach the filter cartridge 6.
- Drain water (under pressure) from water separator 8
by turning the drain screw 7.
The filter cartridge 6 ensures that dirt and condensation
water are removed.
- Disconnect sewing machine from air pressure supply.
- Secure drain screw 7.
The pneumatic system of the sewing machine must be
relieved from pressure.
- Remove water separator 8.
- Remove filter cartridge 6.
Clean filter shell and cartridge with
cleaning spirit (do not use solvents!) and blow
dry.
- Assemble water separator 6 and connect
maintenance unit.
40
500
500
1-24
5
4
2
4
6
8
10
8
7
6