Beisler 1225-5 User Manual
Page 29

Adjusting the holding stamp
Via this parameter the holding stamp is adjusted.
Parameter 15:
Time when the stamp lowers.
Setting range:
0 …20
Parameter 16:
Time how long the warp separator remains switched
on.
Setting range:
0 …100
Parameter 17:
Switch the stacker on or off
Setting range:
0 / 1
Parameter 47:
Time of stacker movement
Setting range:
0 …2000
Parameter 57:
Time how long the holding stamp is down
Setting range:
0 …2000
Altering the machine parameters
Parameter 30:
Set the main speed
Setting range:
0 …8500
Parameter 31:
Switch manual sewing on or off
Setting range:
0 / 1
Parameter 32:
Number of stitches how long the table blowing
remains switched on
Setting range:
0 …400 stitches
Parameter 34:
Number of stitches until the contour guide
lowers
Input:
0 …400 stitches
Parameter 44:
Number of stitches until the contour guide
lowers
Input:
0 …200
Parameter 60:
Softstart speed
Setting range:
500 ...5000
Parameter 61:
Switch the softstart on or off
Setting range:
0 / 1
Parameter 76:
Switch the start via light barrier on or off
Setting range:
0 / 1
Parameter 77:
Switch the autostart on or off
Setting range:
0 / 1
Parameter 78:
Number of stitches when the autostart starts
Setting range:
0 ...400 stitches
Parameter 98:
Switch the lining clamp on or off
Setting range:
0 / 1
25
1