4.15 Serial Interface COM2

The serial interface is a standard IDC socket connector with a spacing of 2.54 mm. Signals default to
RS-232 but can also be ordered as RS-422 or RS-485.
The port address and the interrupt are set via the BIOS setup.

C

AUTION

COM 1 & 2 cables are not the same pin orientation and you may damage the COM interface and CPU
attached if you use the incorrect COM cable.


Description

Name

Pin

Name

Description

data carrier detect

DCD

1

2

DSR

data set ready

receive data

RXD

3

4

RTS

request to send

transmit data

TXD

5

6

CTS

clear to send

data terminal ready

DTR

7

8

RI

ring indicator

ground

GND

9

10

VCC

5 volt supply

Pinout with RS422/485 soldering option:

Description

Name

Pin

Name

Description

transmit data +

TX

1

2

TX#

transmit data -

receive data +

RX

3

4

RX#

receive data -

reserved

N/C

5

6

N/C

reserved

reserved

N/C

7

8

N/C

reserved

ground

GND

9

10

VCC

5 volt supply

This manual is related to the following products: