2 power supply – BECKHOFF CB4050 User Manual
Page 16

Chapter: Connectors
Power Supply
page 16
Beckhoff New Automation Technology CB4050
4.2 Power Supply
The connector for the power supply is a standard IDC socket connector with a spacing of 2.54 mm.
The board only requires an operating voltage of 5 volt ± 5%. 3.3V output to the PC/104-Plus bus is the
only off-board supply available.
Should additional voltages be needed for PC/104 expansion cards, these must be provided externally by
connecting the respective pins (see below).
For maximum current availability, it is recommended to use both this power connector and the PC/104
connector for power supply.
N
OTE
For "Real Time Clock" an external battery (3.3V) must be connected. You can use pins 1 & 3 here or the
"System" connector (see next page).
Description
Name
Pin
Name
Description
ground
GND
1
2
VCC
5 volt supply
CMOS battery >= 3 volt
VBAT
3
4
12V
12 volt supply
-5 volt supply
-5V
5
6
-12V
-12 volt supply
ground
GND
7
8
VCC
5 volt supply