Scenario 2

Volume rate of flow

Pump

Start-up

phase

1

st

cut

Constant

cut

Exit

Move-out

phase

Tool drive active

Cooling lubricant consumption

Energy consumption

Fig. 3 Fractional optimised control

Similar to the example above, the pump is linked logically to the tool drive. However, additionally, there is a valve to regulate
the flow rate for different load cases and to prevent pumping when the tool is driving in. Although the cooling lubricant
consumption is thus optimised, the pump is still running at 100 % utilisation, even though the flow rate is only minimal.
Furthermore, a dynamic pressure builds up at the valve due to the constantly running pump, so that when the valve is opened
the cooling lubricant shoots out before the normal pumping pressure has been established.