Cable sets between receiver and control panel, Connecting cables – BECKHOFF C9900-A172 User Manual
Page 16
Installation Instructions
Cable sets between receiver and Control Panel
Order number
Denomination
C9900-K510
Connection set for CP68xx consisting of:
DVI cable 3 m, USB cable 3 m and power supply
connector
C9900-K514
Connection set for CP78xx consisting of:
DVI cable 3 m, USB cable 3 m and power supply
connector; IP-65 connector at the Control Panel
Connecting cables
The connections are located at the front of the modules and are
documented in Section
Please refer to the respective instruction manuals regarding the
configuration of the connections at the Industrial PC (if a PCI bus
transmitter card is used) and at the Control Panel.
When connecting cables, please adhere to the following order:
• Switch off the Industrial PC
• Disconnect the Industrial PC from the power supply
• Connect all cables at the modules, the Control Panel, and the
devices to be connected
• Ensure that all screw connections (if present) between plug
connectors and sockets are tight!
• Connect the DVI/USB extension modules with the 24 V power
supply. The PCI bus transmitter card is supplied via the Industrial
PC.
• Reconnect all devices to the power supply.
CAT 7 cable with RJ 45
connector
Two standard CAT 7 cables with RJ 45 connector are used for the
connections between transmitter module and receiver module, and
transmitter card and receiver module.
DVI/USB extension C9900-A17x
15