beautypg.com

Dvi-out (x50, x51, x52, x53) (standard dvi cable), Led diagnostics – BECKHOFF CU8810-0000 User Manual

Page 7

background image

Product Description


DVI-OUT (X50, X51, X52, X53) (standard DVI cable)

DVI-Out

Pin

Assignment

Pin

Assignment

1

TMDS Data 2 -

13

Not connected

2

TMDS Data 2 +

14

+ 5 V Power

3

TMDS Data 2/4 Shield

15

Ground ( + 5 V, Analog H/V
Sync)

4

Not connected

16

Hot Plug Detect

5

Not connected

17

TMDS Data 0 -

6

DDC Clock

18

TMDS Data 0 +

7

DDC Data

19

TMDS Data 0/5 Shield

8

Analog Vertical Sync

20

Not connected

9

TMDS Data 1 -

21

Not connected

10

TMDS Data 1 +

22

TMDS Clock Shield

11

TMDS Data 1/3 Shield

23

TMDS Clock +

12

Not connected

24

TMDS Clock -


LED Diagnostics

LED Diagnostics

The following table shows the possible states for the LEDs:

LED Assignment

Status

Meaning

off

No power supply connected

P10 Power

supply

lights green

24 V

DC

connected

off

USB is operational

P20 USB/IN

Port

lights red

USB is in suspend mode/ no device
connected

off

No 15 V supplied to USB/E Port

P30 USB/E

Port 0

lights green

15 V supplied to USB/E Port

off No

suspend

P31 USB/E

Port 0

lights yellow

Suspend

off

No 15 V supplied to USB/E Port

P32 USB/E

Port 1

lights green

15 V supplied to USB/E Port

off No

suspend

P33 USB/E

Port 1

lights yellow

Suspend

off

No 15 V supplied to USB/E Port

P34 USB/E

Port 2

lights green

15 V supplied to USB/E Port

off No

suspend

P35 USB/E

Port 2

lights yellow

Suspend

off

No 15 V supplied to USB/E Port

P36 USB/E

Port 3

lights green

15 V supplied to USB/E Port

off No

suspend

P37 USB/E

Port 3

lights yellow

Suspend


CU8810-0000

5