BECKHOFF CU8810-0000 User Manual
Page 12
Operating Instructions
PWRDVI 2
PWRDVI2
Function
on
DVI Input Port 1 is activated
off
DVI Input Port 1 is deactivated
OUT-LEVEL
The next switch 3 is used to set the back termination for the output level.
The use of back terminations is highly recommended for best signal
integrity.
i
Note
This switch is set to off by factory and should only be changed after
consultation with the Beckhoff Support.
OUT-LEVEL Function
on
No back termination is used
off
Back termination is used
Switch 5 and 6
Switch 5 and 6 are paired to select the source for the DDC signal for
DVI Input Port 0. The DCC signal from the selected port is send to the
device connected to DVI Input Port 0.
The following table shows the possible selections.
5
6
Function
off
off
The DDC-channel from DVI Input Port 0 (X40) is connected to
DDC-channel to DVI Output Port 0 (X50)
on
off
The DDC-channel from DVI Input Port 0 (X40) is connected to
DDC-channel to DVI Output Port 1 (X51)
off
on
The DDC-channel from DVI Input Port 0 (X40) is connected to
DDC-channel to DVI Output Port 2 (X52)
on
on
The DDC-channel from DVI Input Port 0 (X40) is connected to
DDC-channel to DVI Output Port 3 (X53)
Switch 7 and 8
Switch 7 and 8 are paired to select the source for the DDC signal for
DVI Input Port 1. The DCC signal from the selected port is send to the
device connected to DVI Input Port 1.
The following table shows the possible selections.
7
8
Function
off
off
The DDC-channel from DVI Input Port 1 (X41) is connected to
DDC-channel to DVI Output Port 0 (X50)
on
off
The DDC-channel from DVI Input Port 1 (X41) is connected to
DDC-channel to DVI Output Port 1 (X51)
off
on
The DDC-channel from DVI Input Port 1 (X41) is connected to
DDC-channel to DVI Output Port 2 (X52)
on
on
The DDC-channel from DVI Input Port 1 (X41) is connected to
DDC-channel to DVI Output Port 3 (X53)
10
CU8810-0000