beautypg.com

Dayton propane construction heater, 3vg81 – Dayton 3VG81 User Manual

Page 2

background image

Dayton Operating Instructions and Parts Manual

3VG81

2

Dayton Propane
Construction Heater

®

General Safety Information

IMPORTANT: Make certain you read and
understand all warnings. Keep these
instructions for reference. They are your
guide to safe and proper operation of this
heater.

Safety information appears throughout
these instructions. Pay close attention to
them. Below are definitions for the safety
information listed throughout this manual.

Under this heading,
installation, operating

and maintenance procedures or practices
will be found that, if not carefully followed,
WILL result in IMMEDIATE serious personal
injury or death.

Under this heading,
installation, operat-

ing, and maintenance procedures or
practices will be found that, if not
carefully followed, COULD result in severe
personal injury or death.

Under this heading,
installation, oper-

ating, and maintenance procedures or
practices will be found that, if not carefully
followed, MAY result in minor personal injury,
product or property damage.

IMPORTANT: Not every possible circum-
stance that might involve a hazard can be
anticipated. The warnings in this manual
and on tags or decals affixed to the unit are
therefore not all-inclusive. If a procedure, work
method, or operating technique not specifi-
cally recommended by Dayton is used, you
must make sure it is safe for you and others.
You should also ensure that equipment will
not be damaged or made unsafe by the
operating or maintenance method you
choose.

3VG81 Specifications

Output Rating

150,000 Btu/Hr

Fuel

Propane Vapor Only

Fuel Consumption

7.0 Pounds/Hour (1.6 Gallons/Hour)

Regulator Input Pressure

Minimum:

10 Psig

Maximum: Tank Pressure

Regulator Output Pressure

12.5" WC (Factory Preset)

Manifold Pressure

9.8" WC (Factory Preset)

Ignition

Electronic direct spark, D.S.I.

Ignitor Gap

Minimum:

0.13"

Maximum: 0.15"

Temperature Control

Built-In Thermostat

Air Flow

550 Cfm

Volts

120 Vac 60 Hz I Phase

Amps

2.2

Motor HP

1/8

Motor RPM

3,450

Dimensions

36

1

/

4

"L x 20"H x 14

1

/

2

"W

Heater Weight

27 Lb

Shipping Weight

35 Lb

Figure 2 - Product Identification

Product Identification

Hot Air Outlet
(Front)

Handle

Upper Shell

On/Off Switch

Power
Cord

Hose/Regulator
Assembly

Inlet Connector

Lower Shell

Thermostat
Knob

Fan Guard