beautypg.com

Fitting the cable, Material for assembling the connectors, Assembling the connectors – BECKHOFF C5210 User Manual

Page 21: 3 fitting the cable

background image

Installation

3.4.3 Fitting the cable

Fit the cables for the power supply of the Industrial PC, the connection of the battery pack as well as the
connection of the power-switch in accordance with the wiring diagram, using the included material for
assembling the connectors.

Material for assembling the connectors

Plug connector 8-pole, Strain relief housing with lacing cord

Assembling the connectors

The connector is specified for 16 A and can lift conductive cross-sections until 1.5 mm

2

.

So the connector is fitted to the cable:

1. Strip insulation from the cable ends (Length of stripped conductor is 8 – 9 mm).

2. Screw together the cable ends in the 8-pole plug connector in accordance with wiring diagram.

Thread the lacing cord into that lower part of the strain relief
housing.

Put the plug connector into that lower part of the strain relief
housing.

Tighten the lacing cord and pinch off the plastic strap.

Fix the upper part of the strain relief housing by snapping it onto the
lower part.

C5210

19