6

11. TECHNICAL DATA

Housing: self extinguishing ABS
Case:
face 100x64 mm; depth 45.5mm
Mounting: J-box or wall-mount option
Frontal protection: IP65
Connections:

¼” fast-on for power, 1/8” fast-on for probes and Digital Inputs

Power supply: 120Vac

±

10%, optional 230Vac

±

10%

Power absorption: 4VA max.
Display
: 3 digits, red LED, 14,2 mm high.
Inputs: 1 NTC probe
Digital inputs: 2 free voltages
Relay outputs: Dry Contacts

Light: relay SPST 16A, 120Vac;
Alarm: relay SPST 8A, 120Vac

Other output: alarm buzzer
Data storing: on the non-volatile memory (EEPROM).
Measuring and regulation range:

NTC probe: -40÷110°C (-58÷230°F)

Resolution: 1 °F
Accuracy : ±1 °F

12. CONNECTIONS

Power supply: 120Vac +/- 10% 15A MAX current

Full P/N Ambient Temp / %RH

Date Code