beautypg.com

Inspecting burners, Operating fireplace – Desa (V)VC42NE User Manual

Page 24

background image

24

www.desatech.com

116237-01A

OPERATING FIREPLACE

To Turn Off Gas To Appliance
Optional Remote Operation
Operating Optional Blower Accessory

INSPECTING BURNERS

Pilot Assembly
Burner Flame Pattern

TO TURN OFF GAS

TO APPLIANCE

1. Turn off the wall switch.

2. Turn off all electric power to the appliance if service is to

be performed.

3. Open lower louver panel.

4. Remove front hearth brick and control access panel.

5. Turn equipment shutoff valve clockwise

to OFF.

Do not force.

6. Close lower louver panel.

Figure 43 - Pilot

Sensing Rod

Pilot Burner

Ignitor

OPTIONAL REMOTE

OPERATION

Note:

The WRC receiver and hand-held remote control kit

must be purchased separately (see Accessories, page 34). Follow

installation instructions on page 22.

1. Turn equipment shutoff valve to ON position. You can now turn

the burner on and off with the hand-held remote control unit.

IMPORTANT:

Be sure to press the ON/OFF buttons on the

hand-held remote control unit for up to 3 seconds to assure

proper operation.

2. Press the ON/OFF button to turn the burner on and off.

OPERATING OPTIONAL

BLOWER ACCESSORY

Locate the blower controls by opening the lower louver panel

on the fireplace. Blower controls are located on the left side of

the switch bracket to the right just inside the louver panel.
The BK manual blower and the BKT thermostatically-controlled

blower have an ON setting and an OFF setting. The blower

will only run when the switch is in the ON position. In the OFF

position, the blower will not operate.
Note for BKT Only:

If you are using BKT blower with optional

thermostat (wall mounted or remote control) for the fireplace,

your fireplace and blower will not turn on and off at the same

time. The fireplace may run for several minutes before the blower

turns on. After the heater modulates to the pilot position, the

blower will continue to run. The blower will shut off after the

firebox temperature decreases.
The blower helps distribute heated air from the fireplace. Peri-

odically check the louvers of the firebox and remove any dust,

dirt or other obstructions that will hinder the flow of air.

BURNER FLAME PATTERN

Burner flames will be steady; not lifting or floating. Flame patterns

will be different from unit to unit and will vary depending on instal-

lation type and weather conditions.
If the vent configuration is installed incorrectly, the flames will lift

or "ghost". This can be dangerous. Inspect the flames after instal-

lation to ensure proper installation and performance.
Figure 45 shows a typical flame pattern.
If burner flame pattern differs from that described:
• turn fireplace off (see To Turn Off Gas to Appliance)
• see Troubleshooting, page 26

Figure 45 - Typical Flame Pattern

Pilot Burner

Ignitor/Sensor

INSPECTING BURNERS

Check pilot flame pattern and burner flame patterns often.

PILOT ASSEMBLY

The pilot assembly is factory preset for the proper flame. Altera-

tions may have occurred during shipping and handling. The pilot

is located on the left hand side of the burner.
The flame must envelope 1/4" of top of the ignitor/sensor and

grounding stem.
If your pilot assembly does not meet these requirements:
• Turn the adjustment screw marked PILOT clockwise to decrease

or counterclockwise to increase the flame to proper size (see

Figure 42, page 23). Do not remove the adjustment screw.

• see Troubleshooting, page 26

Figure 44 - Correct Pilot Flame Pattern

Sensing Rod

OPERATING FIREPLACE

Continued