Aviosys 9211 User Manual
Page 41
![background image](https://www.manualsdir.com/files/773205/content/doc041.png)
{Add username and password in command line.} For all IE version, include 7.0 and above
User
s
can
contr
ol
the
9222
’s
actio
n directly though the HTTP orders.
The syntax of the HTTP commands are listed below:
Command format:
http://admin:password@ipaddress/Set.cmd?CMD=CmdType
*Http Function of 9211:
GetIO
Command format: http://admin:pasword@ ipaddress/Set.cmd?CMD=getio
http://admin:[email protected]/Set.cmd?CMD=getio
Output Message will return:
P51=0, P52=1, P53=0, P54=1, P55=0, P56=1, P57=0, P58=1
What this means is:
P5
: Represents that this input message is from 9201 Input Module
(The P51 corresponds to the output port number. P51 = Input Module Port 1 P52 = Input Module Port 2
and so on).
The 0/1 after each Output
: Represents whether there has been a status change or not.
0 = Keep Current Status
1 = Change Current Status
So for our current output message:
P51=0,P52=1P53=0,P54=1P55=0,P56=0,P57=0,P58=1HTTP/1.0 200 OK Connection: close
P52 = 1: Output 2: Status - On
P57 = 0: Output 7: Status - Off
P58 = 1: Output 8: Status - On
http://admin:[email protected]/Set.cmd?CMD=GetIo
Please refer to the chart provided for more information:
Input Number (Default)
Default Status
Status Change
Input 1: Wet
Status = Off
Status = On
Input 2: Wet
Status = Off
Status = On
Input 3: Wet
Status = Off
Status = On
Input 4: Wet
Status = Off
Status = On
Input 5: Dry
Status = On
Status = Off
Input 6: Dry
Status = On
Status = Off
Input 7: Dry
Status = On
Status = Off
Note:
IP Power 9202 Output Pro has predefined Relay Statuses.
Outputs 1 - 4:
Normal Closed Relay
(NC)
Outputs 5 - 8:
Normal Open Relay
(NO)
(The relay status of the outputs cannot be changed: Meaning that Output 1-4 will
always be
Normally closed
and Outputs 5-8 will always be
Normally Open
)
41