beautypg.com

Dayton professional-duty electric generators – Dayton 3WY47 User Manual

Page 2

background image

Dayton Operating Instructions and Parts Manual

3WY47, 3W735B, 3W736C, 3WY44, 3TE27A, 3WY45, and 3WY46

2

Dayton Professional-Duty
Electric Generators

®

Specifications

ELECTRICAL SPECIFICATIONS

Rated

Rated Amperage

Rated Amperage

Model

Wattage*

120V

240V

3W735B

2,200

18.3

3W736C

4,000

33.3

16.7

3WY44

5,000

41.7

20.8

3WY46

5,000

41.7

20.8

3TE27A

6,000

50

25

3WY45

7,000

60

30

3WY47

10,000

83.3

41.7

* Single-phase, 1.0 power factor
NOTE: Ratings apply to SAE standard conditions. Reduce ratings 3

1

/

2

% for each 1000 feet above sea level and 1% for each 10

°F rise

above 60

°F.

Honda

Honda

Fuel

Fuel Tank

Oil Alert

Electric

Weight

Model

Engine H.P.

Model

Type

Capacity

System

Start

(pounds)

3W735B

5.5

GX160K1VX

Gasoline

3.9 qt.

Yes

No

85

3W736C

8

GX240K1VA

Gasoline

5 gal.

Yes

No

139

3WY44

9

GX270VA

Gasoline

8 gal.

Yes

No

173

3WY46

9

GX270VDE

Gasoline

8 gal.

Yes

Yes

175

3TE27A

11

GX340K1VA

Gasoline

8 gal.

Yes

No

191

3WY45

13

GX390K1VXE

Gasoline

8 gal.

Yes

Yes

247

3WY47

20

GX620VXA3

Gasoline

13 gal.

Yes

Yes

347

GENERAL SPECIFICATIONS

120V

120V, 30-Amp

120/240V, 20-Amp

120/240V, 30-Amp

120/240V, 50-Amp

120V Full

Model

Duplex

Twist-Lock

Twist-Lock

Twist-Lock

Receptacle

Power Switch

3W735B

Yes

No

No

No

No

No

3W736C

Yes

Yes

Yes

No

No

Yes

3WY44

Yes

Yes

Yes

No

No

Yes

3WY46

Yes

Yes

Yes

No

No

Yes

3TE27A

Yes

Yes

Yes

No

No

Yes

3WY45

Yes

Yes

No

Yes

No

No

3WY47

Yes

Yes

No

Yes

Yes

No

RECEPTACLE SPECIFICATIONS

ELECTRICAL COMPONENT SPECIFICATIONS

Resistance in Ohms

Stator

Stator

Rotor

Rotor

Capacitor,

Main

Auxiliary

Primary

Secondary

MFD

Diodes (2)

Model

Winding *

Winding

Winding †

Winding †

450 Volt

800 Volt

3W735B

1.95

5.2

6.79

1.31

16

6 Amp

3W736C

0.71

2.17

0.54

2.07

40

70

3WY44

0.54

1.38

0.61

2.29

50

70

3WY46

0.54

1.38

0.61

2.29

50

70

3TE27A

0.37

1.01

0.68

2.57

60

70

3WY45

0.28

0.78

0.77

2.9

70

70

3WY47

0.40

0.90

0.37

0.50

80

70

(*) Connect T2 (Green) and T3 (Black). Measure resistance between T1 (Red) and T4 (Yellow).
(

∆) Resistance between brown and white leads.

(†) Remove diodes to check resistance.