beautypg.com

Operation (continued), Dayton operating instructions and parts manual 15, Ho ur s 1 /10 – Dayton 3WY47 User Manual

Page 15: Of f en gin e

background image

Dayton Operating Instructions and Parts Manual

15

Version B - For Reduction

G016.J

®

Models 3WY47, 3W735B, 3W736C, 3WY44, 3TE27A,
3WY45, and 3WY46

Figure 29– Choke Lever Opened
(Model 3WY47 Only)

Choke

Button

(Open

Position)

5. As engine warms up, slowly move

choke lever fully to the right (See Figure
28). This opens the choke. On Model
3WY47, the choke will automatically
open (See Figure 29).

Figure 28 – Choke Lever Opened

Choke Lever (Open Position)

Operation (Continued)

AUTO-IDLE OPERATION

IMPORTANT: Never start engine with
electrical loads connected. Start engine
before adding electrical loads.

1. If engine is cold, turn the auto-idle

switch OFF.

2. Start engine. Allow engine to warm up

with no load for five minutes.

3. Turn auto-idle switch ON. Engine will

slow to idle speed. Engine idle speed is
preset. Idle speed adjustment should
not be necessary.

4. Operate generator according to

specifications outlined in owner's
manual.

5. Engine will automatically increase to

normal operating speed when you plug
load into any generator outlet.

NOTE: The 250 Volt/50 Amp receptacle is
not connected through the auto-idle
circuit. The auto-idle switch must be
turned off to get full power out of this
receptacle (See Figure 30).

6. The auto-idle system should be turned

OFF when generator is shut down.

ADJUSTING THE IDLE SPEED

IMPORTANT: Adjust the idle speed only:

• If the idle speed becomes too high.

• If the engine idle speed will not

regulate (engine idles and speeds up
again and again).

1. Turn auto-idle switch OFF. Start engine.

Allow engine to warm up with no load
for five minutes.

2. Remove engine linkage cover (Models

3WY46 and 3WY45 only).

3. Push plunger into solenoid body to

manually engage solenoid and set idle
speed.

4. Loosen the M8 nut that holds the

solenoid mounting bracket to the
generator (Models 3WY46 and 3WY45
only, See Figure 31). Do not loosen bolt
that holds the solenoid mounting
bracket to the generator on Model
3WY47, See Figure 32).

Figure 30 - Auto-Idle Switch Location on
Control Panel

RE

SE

T

TE

ST

120

V

OL

TS

RESET

240 VOLTS

RESET

RESET

RESET

EN

M

0000

00

05

HO

UR

S 1

/10

120

ONLY

120

240V

OF

F

EN

GIN

E

Figure 31 - Solenoid Bracket Location
(Models 3WY46 and 3WY45 Only)

Figure 32 - Solenoid Bracket Location
(Model 3WY47 Only)

Solenoid

Mounting

Bracket

M8 Nut

Solenoid

Mounting

Bracket

Bolt

Auto-Idle

Switch

This manual is related to the following products: