Use receptacles properly. Improper use
could damage generator. Use only
grounded extension cords. Power only
grounded or double-insulated items. Do
not overload receptacles. Models
3W736C, 3WY44, 3WY46, 3TE27A, and
3WY45 have the following receptacles
(See Figure 21):

• 120V, 15-amp duplex receptacle

• 120V, 15-amp duplex GFCI receptacle

• 120V, 30-amp twist-lock receptacle

• 120/240V, 20 or 30-amp twist-lock

receptacle

Model 3W735B has only the 120V duplex
receptacle.

POWER CORD AND PLUG REQUIREMENTS

120V, 30-amp twist-lock receptacle

• NEMA L5-30P plug
• Three-wire, 30-amp cord

120/240V, 20 or 30-amp twist-lock receptacle

• NEMA L14-20P (20-amp) or L14-30P

(30-amp) plug

• Four-wire, 20-amp or 30-amp cord

120V/240V, 50-amp twist-lock receptacle

• NEMA L14-50P plug
• Four-wire, 50-amp cord

Figure 22 – Receptacle Locations
(Model 3WY47 only)

120V, 30-Amp

Twist-Lock

120/240V, 20 or 30-Amp

Twist-Lock

120V, 15-Amp Duplex

Figure 21 – Receptacle Locations (Models
3W736C, 3WY44, 3WY46, 3TE27A, and
3WY45)

W

(Neutral)

X

(Hot)

Ground
(Green)

120 Volt

30 Amp

G

W

X

L5-30P
Plug

Figure 23 – Cord and Plug Configurations

Model 3WY47 has the follwing receptacles
(See Figure 22):

• 120V, 15-amp duplex GFCI receptacle

• 120V, 15-amp duplex receptacle

• 120V, 30-amp twist-lock receptacle

• 120/240V, 30-amp twist-lock receptacle

• 120/240V, 50-amp receptacle

RESET

TEST

120 VOLTS

RESET

240 VOLTS

OFF

Auto-Idle

ON

RESET

RESET

RESET

ENM

00000005

HOURS 1/10

120V, 15-Amp GFCI

120/240V, 50-Amp

w

G

Y

X

w

G

Y

X

120V

120V

Neutral

Ground

Ground

X

(Hot)

W

(Neutral)

Y

(Hot)

Ground
(Green)

L14-30P
Plug

L14-20P
Plug

120V

120V

Neutral

w

G

Y

X

Ground L14-50P

Plug

120/240 Volt

20 and 30

Amp

120V

120V

Neutral

Operation

HIGH AND LOW TEMPERATURE
OPERATION

Air temperature affects generator output.
Output drops 1% for each 10

° tempera-

ture rise above 60

° F. Very low tempera-

tures may make the engine hard to start.
See engine owner’s manual for more
information.

GENERAL INFORMATION

This generator is not large enough to
power your entire home. Do not connect
generator to any existing electrical circuits.
Plug items directly into generator recep-
tacles. Do not exceed amperage rating of
receptacles. Only use grounded cords.

Use only in well-
vented areas. Make

sure area has plenty of free-moving,
fresh, outside air. Never run generator in
an enclosed or confined area. Never run
generator inside occupied building.
Engine exhaust contains poisonous
carbon monoxide gas. Overexposure will
cause loss of consciousness and will lead
to death.

Never connect
generator to any

existing electrical circuits. The genera-
tor output will back-feed into the
utility power line. This may electrocute
a power company line repair person.
Also, if generator is powering electri-
cal circuits, the chance of an electrical
fire exists.

NOTE: We supply the engine owner’s
manual with generator. Refer to that
manual for questions concerning engine
operation.

USING RECEPTACLE

NOTE: Do not exceed amperage rating of
receptacles. Exceeding rating will trip
receptacle circuit breaker.