Installation
(for qualified installers only)
7
© Travis Industries
4041213
1 0 0 - 0 1 1 5 2
Installation Warnings:
•
Failure to follow all of the requirements may result in property damage, bodily
injury, or even death.
•
This heater must be installed by a qualified installer who has gone through a
training program for the installation of direct vent gas appliances.
•
This appliance must be installed in accordance with all local codes, if any; if not,
follow ANSI Z223.1 and NFPA 54(88).
•
In Manufactured or Mobile Homes must conform with Manufactured Home
Construction and Safety Standard, Title 24 CFR, Part 3280, or, when such a
standard is not applicable, the Standard for Manufactured Home Installations,
ANSI/NCSBCS A225.1. This appliance may be installed in Manufactured Housing
only after the home is site located.
•
The fireplace is designed to operate on natural gas, or propane (LP).
•
All exhaust gases must be vented outside the structure of the living-area.
Combustion air is drawn from outside the living-area structure.
•
Notify your insurance company before hooking up this fireplace.
•
The requirements listed below are divided into sections. All requirements must be
met simultaneously. The order of installation is not rigid – the qualified installer
should follow the procedure best suited for the installation.
Packing List
• Propane Conversion Kit
• Log Set (3 Logs, 2 Twigs, Bag of Coals, Coal Trays)
• Restrictor Adjuster Rod
• Flex Tube with Pipe Adapter
Additional Items Required
•
Faceplate
•
Direct Vent (Simpson Dura-Vent Ph. # 800 835-4429)
•
Gas Line Equipment (shutoff valve, pipe, etc.)
•
Electrical Equipment
Installation Overview
Non-combustible facing (see
"Facing Requirements")
See "Horizontal
Termination
Requirements"
See "Electrical
Connection"
See "Mantel Requirements"
Insulation must not fill
the spaces between
the stand-offs
See "Fireplace Placement Requirements"
The faceplate
must be 6"
minimum from
side walls.
See "Vent Requirements"
See "Minimum
Framing
Dimensions"
See "Hearth Requirements"
Drywall
Nail Down Plate
See "Gas Line
Installation"
See
"Acceptable
Vent Lengths"
Optional thermostat or remote control wire.