Features and specifications, Features, Installation options – Avalon Firestyles DVS Fireplace-1997 to 2000 User Manual
Page 5: Heating specifications, Dimensions, Eatures and, Pecifications

F
EATURES AND
S
PECIFICATIONS
P
AGE
5
Features:
-
Works During Power Outages (utilizes millivolt system)
-
High Efficiency
-
Optional Thermostat or Remote Control
-
Realistic "Wood Fire" Look
-
Quiet Blower for Effective Heat Distribution
-
Convenient Operating Controls
-
Variable-Rate Heat Output
-
Low Maintenance
Installation Options:
-
Residential or Mobile Home
-
Straight or Corner Placement
-
Flush or Recessed Face
-
Raised or Floor Hearth
-
Internal or External Chase
-
Horizontal or Vertical Vent
Heating Specifications:
Natural Gas
Propane
Approximate Heating Capacity (in square feet)*
500 to 1,500
500 to 1,500
BTU Input Per Hour (from high to low)
31,000 - 18,600
31,000 - 16,000
Efficiency**
up to 80 %
up to 80.5 %
AFUE (Annual Fuel Utilization Efficiency)
71.3 %
71.8 %
*
Heating capacity will vary with the home's floor plan and insulation, natural gas or Propane BTU rating, and outside temperature.
**
Efficiency rating is a product thermal efficiency rating determined under continuous operation independent of installed system.
Vent has an external
diameter of 6-5/8"
Weight: 165 Lbs.
Dimensions:
Electrical access panel is 6"
behind the front, along the base.
1/2"
Stand-offs
* Includes the 1/2"
stand-offs
Nail Down
Plate (used
to secure
the fireplace
to the floor)
See "Gas Line Connection"
on page 22 for more details
2"
37"*
28-1/8"*
28-1/2"
14-1/2"
29-1/8"
20-3/8"
1-1/2"
1"
34-3/4"
2-5/8"
7-3/4"
19-3/8"*
2"
4-7/8"