Finalizing the installation, Removing the glass, Inalizing the – Avalon Firestyles DVS Fireplace-1997 to 2000 User Manual
Page 24: Nstallation

P
AGE
24
F
INALIZING THE
I
NSTALLATION
- For Qualified Installers Only!
!
ACID WASH WARNING
: Before installing the faceplate, make sure any masonry that has been
treated with acid wash has been properly neutralized (this is used primarily with brick faces). Acid
wash (muriatic acid) is used to remove excess mortar. If not properly neutralized with an ammonia
solution, the gold face may develop a permanent tarnish when the acid evaporates over time.
Contact your dealer if uncertain your facing has been properly neutralized.
!
Turn the gas control valve to "OFF" prior to conducting any service.
1
Follow the instructions below to remove the glass.
Cross Section of
Glass Attachment
Glass
Glass Gasket
(3/4" self-adhesive
channel gasket)
Glass Clip
Glass Clip
Attachment Studs
Face of Heater
Glass Clip Nuts
Loosen the nuts on the
top and side glass clips
until they are flush with
the end of the stud (do
not remove the nuts).
a
3/8" Nutdriver
b
While holding the glass,
loosen the nuts on the
bottom glass clip until
they are flush with the
end of the stud. Pivot
the glass forward and
remove.
Tighten the nuts on the
bottom glass clip first, then
the top, then the sides.
Removing the Glass
While holding the glass, slide the
side and top glass clips off.
c
Replacing the Glass
With the bottom glass clip in place and
the nuts flush with the end of the stud,
position the glass over the bottom clip
(do not tighten the nuts).
Replace the top glass clip
(do not tighten nuts).
Center the glass then
replace the side glass clips
(do not tighten nuts).
a
b
c
d