Installation
(for qualified installers only)
7
© Travis Industries
4121130
100-01311
Installation Warnings
!
Failure to follow all of the requirements may result in property damage, bodily injury, or even
death.
!
This heater must be installed by a qualified installer who has gone through a training program
for the installation of direct vent gas appliances.
!
This appliance must be installed in accordance with all local codes, if any; if not, in U.S.A.
follow ANSI Z223.1 and NFPA 54(88), in Canada follow CSA B149.1.
!
A manufactured home (USA only) or mobile home OEM installation must conform with the
Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, or, when such
a standard is not applicable, the Standard for Manufactured Home Installations, ANSI/NCSBCS
A225.1, or Standard for Gas Equipped Recreational Vehicles and Mobile Housing, CSA Z240.4.
!
This stove is designed to operate on natural gas or propane (LP).
!
All exhaust gases must be vented outside the structure of the living-area. Combustion air is
drawn from outside the living-area structure.
!
Notify your insurance company before hooking up this stove.
!
The requirements listed below are divided into sections. All requirements must be met
simultaneously. The order of installation is not rigid – the qualified installer should follow the
procedure best suited for the installation.
Packing List
•
Propane Conversion Kit
• Touch-Up
Paint
•
½” FPT to 3/8” Flare Fitting
•
Rear Vent Cover
•
Driftwood/Stone Conversion Parts
Additional Items Required
•
Vent (see “Venting Requirements” for details)
•
Gas Line Equipment (shutoff valve, pipe, etc.)
•
Approved Travis Media (Logs 94500561, Driftwood
94500562, or Stones 94700733)
Installation Overview
See "Vent
Requirements"
See "Floor
Protection
Requirements"
See "Gas Line
Installation"
See