Installation, Optional wall switch or thermostat installation – Avalon Firestyles Cypress User Manual
Page 11
Installation
(for qualified installers only)
11
© Travis Industries
4121130
100-01311
Optional Wall Switch or Thermostat Installation
Do not connect 110-120 VAC to the gas control valve or wiring system of this stove. The switch must be
installed by a qualified installer.
Caution:
Label all wires prior to disconnection when servicing controls. Wiring errors can cause
improper and dangerous operation.
Note:
When using a GreenSmart™ remote, use the receiver for on/off operation (do not use a wall
switch or thermostat).
Warning:
Make sure all wiring is secure and does not contact hot or moving components.
The wall switch (or thermostat) may bypass the fireplace on/off switch or be installed in
parallel or series configuration (see below).
Parallel Connection
Series Connection
On / Off Switch
ON
On / Off Switch
OFF
On / Off Switch
ON
On / Off Switch
OFF
Thermostat / External
Switch ON
Heater is ON
Heater is ON
Thermostat /
External Switch ON
Heater is ON
Heater is OFF
Thermostat / External
Switch OFF
Heater is ON
Heater is OFF
Thermostat /
External Switch OFF
Heater is OFF
Heater is OFF
To wire the heater in parallel, follow the directions below:
To wire the heater in series, follow the directions below:
Thermostat
(or External Switch) Wires
a
b
c
On / Off Switch
a
On / Off Switch
c
b
Thermostat
(or External Switch) Wires