beautypg.com

ATI Audio DDA416/WC106 User Manual

Page 12

background image

12

 

DDA‐416/WC106 Manual


INSTALLATION


LOCATION

The DDA is readily installed into a 2 RU, 19” rack. The DDA is only to be installed in an inside
location where it is protected from inclement weather. Operate the DDA in temperature range of +5
to +40°C (105°F), with relative humidity ranging from 5 to 85%.


POWER

Connector for socket fused IEC 320/C13. Power cord is supplied. The DDA has a rear panel On
Off power switch.

POWER INPUT SPECIFICATIONS:

Voltage .......................................................................................85 ~ 264Vac
Frequency .....................................................................................47 to 63Hz

This equipment is connected to earth through the center conductor of the AC mains cable. Proper
grounding protects user/operators from electric shock, and it must be maintained whenever the unit
is connected to AC.


WIRING

XLR inputs for external clock sources require special controlled impedance, 110 ohm, low loss, foil
shielded, twisted pair cables. Standard audio cable is not recommended. Belden and most other
cable manufacturers offer special digital audio cabling for this application. BNC connectors use 75-
ohm coax (RG59). Select a cable for losses less than 20dB at 12MHz (for data rates up to 96 k
samples) at the maximum distance you require. Keep cable length as short as possible