beautypg.com

5 bcm8727 status, 6 sfp+ connection, 1 i2c bus – Artesyn RTM ATCA-F140 Installation and Use (September 2014) User Manual

Page 38: 5 bcm8727 status 4.4.6 sfp+ connection, Table 4-6, Sfp+ connector pin assignment, Functional description

background image

Functional Description

RTM-ATCA-F140 Installation and Use (6806800M97G)

38

4.4.5

BCM8727 Status

The PCMULK, PCDRLK, PLOSB and LASI signals from each BCM8727 port are connected to the
RTM FPGA to allow them to be monitored by software. The PLOSB and LASI signals can also
generate an interrupt to the front-blade. Refer to

Chapter 4, FPGA, on page 46

for further

details.

4.4.6

SFP+ Connection

The SFP+ cage accepts industry standard SFP+ optical modules. The SFP+ cage is backwards
compatible with 1 GB optical or copper SFP modules. Refer to the ATCA-F140 Installation and
Use Manual for a list of SFP devices tested with this product. The SFP+ connector assignment
for the 10 Gbps serial interface is described in

Table 4-6

.

4.4.6.1

I2C Bus

The SFP+ I2C bus signals (I2C_SDA and I2C_SCL) from each SFP+ site are individually
connected to the corresponding BCM8727 which includes a mechanism to allow access to the
port through the phy management channel.

Table 4-6 SFP+ Connector Pin Assignment

Pin

Signal

Pin

Signal

1

GND

11

GND

2

TX_FAULT

12

RX-

3

TX_DISABLE

13

RX+

4

I2C_SDA

14

GND

5

I2C_SCL

15

VCCr (+3.3 V)

6

MOD_ABS

16

VCCt (+3.3 V)

7

RS0

17

GND

8

LOS

18

TX+

9

RS1

19

TX-

10

GND

20