Install sfp – Artel DLC274 User Manual
Page 4

www.artel.com | 978-263-5775 | [email protected] | [email protected]
DLC274D Front Panel LEDs
LED
Function
Color
Description
OK
DLC274D
Module
Status
OFF
If power is applied to the system, an internal fault with the DLC274D may exist
n
Green
Normal operation
n
Yellow
If no other status LEDs indicate a minor alarm, then a temperature alarm is indicated
n
Red
If no other status LEDs indicate a major alarm, then an internal error is indicated, such
as an onboard communications error or an onboard power error
EMS
DigiLink Manager
System
Status
OFF
The DLC274D module is in local mode and its configuration is controlled by the
onboard configuration switches
n
Green
The DLC274D module is in remote mode and the configuration has been set by the
EMS. When in remote mode, the actual configuration of the module will likely not
match the settings of the configuration switches and changing the configuration
switches will have no effect on the module operation
TX
Transmitter
Status
OFF
Transmitter is disabled
n
Green
Normal operation (repeating input signal)
n
Red
SFP TX failure exists
Red
No SFP is installed
RX
Receiver
Status
n
Green
Normal operation
n
Yellow
Link errors detected
Yellow
Receive optical power is high
n
Red
No input signal or the input signal type is incorrect (not a valid DLC274M or
DLC274M signal)
Red
Possible causes:
•
A low receiver power condition exists
•
No SFP is installed
•
An SFP RX failure exists
A, B,
C, D
270 Mb/s
Channel
Status
OFF
Channel is disabled on the DLC274D or DLC274M
n
Green
270 Mb/s video detected
n
Yellow
No signal to the DLC274M
n
Red
Video input signal rate is outside the range (270 Mb +/- 100 ppm)
Flashing yellow |
Flashing red
Install SFP
AR208-008030-B00_D
270 Mb/s Digital Video 4-to-1 TDM De-Multiplexer with
Optical Transmitter/Receiver/Repeater [DLC274D]