Artel DLC150E User Manual
Digilink, Artel ships the dlc150e configured as follows, Dip switch configurations
![background image](https://www.manualsdir.com/files/772418/content/doc001.png)
Simplifying Media Transport
™
DigiLink
Media
Transport Simplified
QUICK START GUIDE
SW4 CONFIGURATION SIGNAL SOURCE
Function
Off
On
S4
Audio
Source
AES Digital
Analog
S5
Analog
Audio Mode
20 bits
24 bits
Factory Default: All On
Artel ships the DLC150E configured as follows:
•
Analog audio mode set to 24 bits
•
Analog audio source with 600 ohm termination
•
+20 dB peak audio level without clipping
•
Asynchronous audio embed into destination group #1
•
Digital video enabled through the BNC connector
•
SDI grey field enabled if no video is present at the NTSC rate
•
Alarm enabled if no SFP is present
•
EMS override enabled (DigiLink Manager can change the DLC150E configuration)
DIP Switch Configurations
SW3 CONFIGURATION PEAK AUDIO
LEVEL
SW
Function
0
+10 dBm
1
+12 dBm
2
+14 dBm
3
+16 dBm
4
+18 dBm
5
+20 dBm
6
+22 dBm
7
+24 dBm
Factory Default: +20 dBm
SW2 CONFIGURATION
ANALOG AUDIO TERMINATION
Function
Off
On
S1
Audio Ch D
High Z
600 ohm
S2
Reserved
-
Must be On
S3
Audio Ch C
High Z
600 ohm
S4
Reserved
-
Must be On
S5
Audio Ch B
High Z
600 ohm
S6
Reserved
-
Must be On
S7
Audio Ch A
High Z
600 ohm
S8
Reserved
-
Must be On
Factory Default: All On
SW2
Controls the termination of the
analog audio inputs
SW3
Controls the peak analog audio
(
Rotary
level that can be handled without
Switch)
clipping
SW4
Controls the signal source selection
for the digital video, type of audio,
and destination group for the
embedding
SW5
Controls multiple module
operating states including:
conditional embedding, non-video
keep-alive signal, line rate for the
standby video pattern, digital audio
rate converter operation, optional
alarm suppresssion for an uninstalled
SFP, and EMS control mode
SW5 CONFIGURATION
MODE CONTROL
Audio Embed Mode
S1
S2
Group Embed
(See SW4: S6, S7)
On
On
Always Embed
On
Off
No Embed
Off
Off
Reserved
Off
On
Factory Default: All On
Function
Off
On
S3
Standby Signal
Artel*
SDI Grey
S4
Standby Type
625 Line
525 Line
S5
Rate Converter
Sync
Async
S6
SFP Alarm
Disabled
Enabled
S7
Reserved
-
Must be On
S8
EMS Override
Local
Control
Remote
Control
•Non-video keep-alive signal.
Factory Default: All On
SW4
SW5
SW2
SW3
Configuration Switch Functions
Function
Off
On
S8
Reserved
-
Must be On
Factory Default: On
SW4 CONFIGURATION SIGNAL SOURCE
S1
S2
S3
Video Source
On
On
On
SDI BNC In
Off
Off
Off
Backplane 1
On
Off
Off
Backplane 2
Off
On
Off
Backplane 3
On
On
Off
Backplane 4
Off
On
On
SFP Opt Receiver
Off
Off
On
Reserved
On
Off
Off
Reserved
Factory Default: All On
S6
S7
AUDIO DESTINATION
On
On
Group 1
Off
On
Group 2
On
Off
Group 3
Off
Off
Group 4
Factory Default: All On
SDI/SDTI 4 Channel Analog/Digital AES Audio