beautypg.com

Install sfps – Artel DLC300 User Manual

Page 2

background image

www.artel.com | 978-263-5775 | [email protected] | [email protected]

DLC300 Front Panel LEDs

LED

Function

Color

Description

OK

DLC300

Module

Status

OFF

If power is applied to the system, an internal fault may exist

n

Green

Normal operation

n

Yellow

A temperature alarm is indicated if the RX LED is not flashing yellow

n

Red

The TX or RX LEDs may indicate the cause of the alarm. Loss of video if the video alarm is enabled. Video rate is not

locked.

1

The corresponding signal rate LED will flash red. Possible internal error

EMS

DigiLink Manager

System

Status

OFF

The DLC300 module is in local mode and its configuration is controlled by the onboard configuration switches

n

Green

The DLC300 module is in remote mode and the configuration has been set by DigiLink Manager. When in remote

mode, the actual configuration of the module will likely not match the settings of the configuration switches and

changing the configuration switches will have no effect on the module’s operation

TX

2

Transmitter

(PRI & SEC)

OFF

Receiver mode is selected or the corresponding PRIMARY or SECONDARY SFP is not installed

n

Green

Normal TX operation (input signal present)

n

Yellow

Standby operation (signal from the standby generator)

Red

No SFP is installed in either socket or an SFP TX failure exists

RX

2

Receiver Status

(PRI & SEC)

OFF

Transmitter mode is selected or the corresponding PRIMARY or SECONDARY SFP is not installed

n

Green

Normal RX operation (input signal is present)

n

Yellow

143 Mb PRBS non-video standby signal detected

Yellow

Receive optical power is high

Red

Low light, loss of SFP RX signal, the PRIMARY and SECONDARY SFP sockets are both missing SFPs,

or an SFP RX failure exists

3G

2.97Gb/s

Status

OFF

3G signal is not detected

n

Green

3G signal is received or transmitted

n

Yellow

3G signal is detected and is processed

3

w/EG34 dithering

n

Red

3G signal is detected and blocked

Red

Video rate is unlocked

1

HD

1.485 Gb/s SDI

Signal

Status

OFF

HD signal is not detected

n

Green

HD signal is received or transmitted

n

Yellow

HD signal is detected and is processed

3

w/EG34 dithering

n

Red

HD signal is detected and blocked

Red

Video rate unlocked

1

SD

270 Mb/s SDI

Signal

Status

OFF

SD signal is not detected

n

Green

SD signal is received or transmitted

n

Yellow

SD signal is detected and is processed

3

w/EG34 dithering

n

Red

SD signal is detected and blocked

Red

Video rate unlocked

1

ASI

ASI

Signal

Status

OFF

ASI signal is not detected

n

Green

ASI signal is being received or transmitted

n

Yellow

ASI signal is detected and is processed

3

w/EG34 dithering

n

Red

ASI signal is detected and blocked

Red

Video rate unlocked

1

ATSC

SMPTE 310

19.39 Mb/s ATSC

Signal Status

OFF

SMPTE 310 19.39 Mb/s ATSC signal is not detected

n

Green

SMPTE 310 19.39 Mb/s ATSC signal is received or transmitted

n

Yellow

SMPTE 310 19.39 Mb/s ATSC signal is detected and is being converted to ASI

n

Red

SMPTE 310 19.39 Mb/s ATSC signal is detected and blocked

Flashing yellow |

Flashing red

Install SFPs

1. A video rate unlocked condition usually

indicates that the input signal rate is

outside the standard rate requirements.

The input signal rate requirements are as

follows:

- SDI/ASI rates must be 270 Mb/s + 100 ppm

- HD SDI rate must be 1.485 Mb/s or

1.485/1.001 Mb/s + 50 ppm

- 3G SDI rate must be 2.97 Gb/s or 2.97/1.001

Gb/s + 50 ppm

If the signal cannot be held within these

requirements, try setting the DLC300 to

bypass mode

2. When the DLC300 is in repeater mode, the

TX and RX status LEDs are active to represent

the simultaneous receive and transmit

operations occurring

3. Depending on the operating mode of the

DLC300, it processes the signal as follows:

- Transmitter mode—Dithered

- Receiver mode—Undithered

- Repeater mode—The optical transmit

signal is an unmodified (but reclocked)

copy of the optical receive signal. The

electrical BNC output and monitor output

is undithered if SW3-2 is OFF, otherwise these

outputs are dithered.

(The optical transmit signal is an unmodified

copy of optical receive signal). If a DLC300

in receiver mode is set to undither and an

undithered SDI or ASI signal is received,

the signal will be output normally, without

dithering.

Footnotes

AR208-008120-

C00_F

Optical redundancy is enabled

with installation of secondary

SFP (as shown)

3G-SDI Multi-Rate Digital Video Optical Transmitter/

Receiver/Repeater [DLC300]