DLC300 Front Panel LEDs
LED
Function
Color
Description
OK
DLC300
Module
Status
OFF
If power is applied to the system, an internal fault may exist
n
Green
Normal operation
n
Yellow
A temperature alarm is indicated if the RX LED is not flashing yellow
n
Red
The TX or RX LEDs may indicate the cause of the alarm. Loss of video if the video alarm is enabled. Video rate is not
locked.
1
The corresponding signal rate LED will flash red. Possible internal error
EMS
DigiLink Manager
System
Status
OFF
The DLC300 module is in local mode and its configuration is controlled by the onboard configuration switches
n
Green
The DLC300 module is in remote mode and the configuration has been set by DigiLink Manager. When in remote
mode, the actual configuration of the module will likely not match the settings of the configuration switches and
changing the configuration switches will have no effect on the module’s operation
TX
2
Transmitter
(PRI & SEC)
OFF
Receiver mode is selected or the corresponding PRIMARY or SECONDARY SFP is not installed
n
Green
Normal TX operation (input signal present)
n
Yellow
Standby operation (signal from the standby generator)
Red
No SFP is installed in either socket or an SFP TX failure exists
RX
2
Receiver Status
(PRI & SEC)
OFF
Transmitter mode is selected or the corresponding PRIMARY or SECONDARY SFP is not installed
n
Green
Normal RX operation (input signal is present)
n
Yellow
143 Mb PRBS non-video standby signal detected
Yellow
Receive optical power is high
Red
Low light, loss of SFP RX signal, the PRIMARY and SECONDARY SFP sockets are both missing SFPs,
or an SFP RX failure exists
3G
2.97Gb/s
Status
OFF
3G signal is not detected
n
Green
3G signal is received or transmitted
n
Yellow
3G signal is detected and is processed
3
w/EG34 dithering
n
Red
3G signal is detected and blocked
Red
Video rate is unlocked
1
HD
1.485 Gb/s SDI
Signal
Status
OFF
HD signal is not detected
n
Green
HD signal is received or transmitted
n
Yellow
HD signal is detected and is processed
3
w/EG34 dithering
n
Red
HD signal is detected and blocked
Red
Video rate unlocked
1
SD
270 Mb/s SDI
Signal
Status
OFF
SD signal is not detected
n
Green
SD signal is received or transmitted
n
Yellow
SD signal is detected and is processed
3
w/EG34 dithering
n
Red
SD signal is detected and blocked
Red
Video rate unlocked
1
ASI
ASI
Signal
Status
OFF
ASI signal is not detected
n
Green
ASI signal is being received or transmitted
n
Yellow
ASI signal is detected and is processed
3
w/EG34 dithering
n
Red
ASI signal is detected and blocked
Red
Video rate unlocked
1
ATSC
SMPTE 310
19.39 Mb/s ATSC
Signal Status
OFF
SMPTE 310 19.39 Mb/s ATSC signal is not detected
n
Green
SMPTE 310 19.39 Mb/s ATSC signal is received or transmitted
n
Yellow
SMPTE 310 19.39 Mb/s ATSC signal is detected and is being converted to ASI
n
Red
SMPTE 310 19.39 Mb/s ATSC signal is detected and blocked
Flashing yellow |
Flashing red
Install SFPs
1. A video rate unlocked condition usually
indicates that the input signal rate is
outside the standard rate requirements.
The input signal rate requirements are as
follows:
- SDI/ASI rates must be 270 Mb/s + 100 ppm
- HD SDI rate must be 1.485 Mb/s or
1.485/1.001 Mb/s + 50 ppm
- 3G SDI rate must be 2.97 Gb/s or 2.97/1.001
Gb/s + 50 ppm
If the signal cannot be held within these
requirements, try setting the DLC300 to
bypass mode
2. When the DLC300 is in repeater mode, the
TX and RX status LEDs are active to represent
the simultaneous receive and transmit
operations occurring
3. Depending on the operating mode of the
DLC300, it processes the signal as follows:
- Transmitter mode—Dithered
- Receiver mode—Undithered
- Repeater mode—The optical transmit
signal is an unmodified (but reclocked)
copy of the optical receive signal. The
electrical BNC output and monitor output
is undithered if SW3-2 is OFF, otherwise these
outputs are dithered.
(The optical transmit signal is an unmodified
copy of optical receive signal). If a DLC300
in receiver mode is set to undither and an
undithered SDI or ASI signal is received,
the signal will be output normally, without
dithering.
Footnotes
AR208-008120-
C00_F
Optical redundancy is enabled
with installation of secondary
SFP (as shown)
3G-SDI Multi-Rate Digital Video Optical Transmitter/
Receiver/Repeater [DLC300]