Code 39 – Argox AS-8150 User Manual
Page 46

45
Code 39
Read: Format
Start
“★”
Data Digits
( Variable)
Checksum
(Optional)
End
“★”
Check-sum verification: The checksum of Code-39 is
optional and made as the sum module 43 of the numerical
value of the data digits.
Check-sum transmission: By setting Enable, checksum
will be transmitted.
Max./Min. code length: Each symbology has its own
Max./Min. Code Length. They can be set to qualify data entry.
If their Max./Min. Code Length is zero, the Global Min./Max.
Code Length is in effect. The length is defined as to the
actual barcode data length to be sent. Labels with lengths
that exceed these limits will be rejected. Make sure that the
Minimum length setting is no greater than the Maximum
length setting, or otherwise all the labels of the symbology
will not be readable. In particular, you can see the same
value for both Minimum and Maximum reading length to force
the fixed length barcode decoded.
Truncate leading/ending: Refer to Truncate leading/ending
of UPCA.
Code ID setting: Refer to Code ID setting of UPCA.
Option Bar Code
Option
Alphanumeric
Entry
Read
Disable
Enable
00
01
*
Program