Argox AME-3230 Series User Manual
Page 17

33
AME Series User’s Manual
Status
Blinking LED
SERIAL I/O ERROR
POWER LED blinking
Possible Symptoms & Solutions
The format or baud rate of the RS232 communication is
inconsistent between the printer and host.
Status
Blinking LED
MEMORY FULL
POWER LED blinking
Possible Symptoms & Solutions
The printer memory buffer is fully loaded with downloadable soft
fonts, graphics or forms.
Check the format and size of stored data with available memory
size or call for service.
Status
Blinking LED
Print Head overheated
POWER LED blinking
Possible Symptoms & Solutions
Printer enters PAUSE status to wait for print head to cool down;
printer will resume printing tasks when it is ready.
Performing Calibration
If labels with gaps/black marks are in use, perform media calibration
34
AME Series User’s Manual
before printing to make printer index correctly.
1. Properly install labels.
2. Power off the printer.
3. Press and hold the FEED button then turn on power; do not
release the button until printer starts to feed labels.
4. Then, press FEED button once or twice to check that labels
are correctly indexed.
Printing a Configuration Report
The Configuration report, also known as the Self-Test report, can
work as a printer diagnosis tool. Steps to print a Configuration report
are listed below:
1. Press the Power Button to turn off the printer.
2. Make sure the Battery is installed and media is loaded.
3. Press and hold the Feed Button, and then press the Power
Switch to turn on the printer.
4. After printer starts to print, release the Feed Button.
5. Wait until printer finishes printing, then press the Power Switch
or Feed Button to resume normal printing mode.
Sample printout of Configuration (Self-Test):
Note: You must always carry out calibration when changing
media. Failure to do so will result in improper
detection by the label sensor.