4.2 Compressor Controls
The 527 Compressor provides a comprehensive suite of controls:
•
THRESHOLD: The level at which compression begins
•
ATTACK: The time it takes for the compressor to respond
•
RELEASE: The time it takes the compressor to return to unity gain
•
RATIO: The amount of compression applied after threshold
•
TYPE: NEW or OLD detection path topology
•
KNEE: The characteristic of the response curve at the onset of compression.
•
THRUST®: Patented circuit that inserts a high-pass filter before the RMS detector
•
GR Meter (GAIN REDUCTION): 10 LED gain reduction meter
•
LINK: Activates the DC LINK for stereo/multichannel processing with other TCS units
•
COMP BYPASS (Compressor Bypass): Completely removes the 527 Compressor from
•
POST EQ: Moves the 527 Compressor to post the 550A Equalizer in the audio path
4.2.1 Threshold
THRESHOLD: Sets the level at which compression begins
•
Continuously variable between +10dBu and -20dBu
•
Detented rotary pot for easy recall
4.2.2 Attack and Release
Attack and Release times are fully variable on the 527 Compressor and share a
dual-concentric potentiometer for control. Attack time is adjusted using the
outer ring of the pot and Release time is adjusted using the inner knob.
ATTACK: Sets the time it takes the compressor to react when the level exceeds
the set THRESHOLD
•
Continuously variable between 1 and 25 ms (milliseconds)
•
Detented rotary pot for easy recall