DLM 600W Series

Isolated Remote Analog Interface Operation

M51A Option

2-9

4.

Program the other parameters to the desired limit values: VOLTAGE PROGRAMMING
INPUT, Pin-9, and the CURRENT PROGRAMMING INPUT, Pin-10, with respect to
Pin-12.


5.

Connect Pin-1, ANALOG-CONTROL, of the ISOLATED ANALOG INTERFACE
connector to Pin-15.

2.4.4 Resistance

Programming of Output Voltage


Setting up for resistance programming of the output voltage is as follows:

1.

Set Position-1, V, of the INTFC SETUP switch to OFF (down) for 0-5VDC programming
range.


2.

Connect the external programming resistance, 0-5kΩ, to the ISOLATED ANALOG
INTERFACE connector, from Pin-21 to Pin-12.


3.

Connect a jumper from Pin-21 to Pin-9.


4.

Program the other parameters to the desired limit values: CURRENT PROGRAMMING
INPUT, Pin-10, and the OVP PROGRAMMING INPUT, Pin-3, with respect to Pin-12.


5.

Connect Pin-1, ANALOG-CONTROL, of the ISOLATED ANALOG INTERFACE
connector to Pin-15.

2.4.5 Resistance

Programming of Output Current


Setting up for resistance programming of the output current is as follows:

1.

Set Position-2, I, of the INTFC SETUP switch to OFF (down) for 0-5VDC programming
range.


2.

Connect the external programming resistance, 0-5kΩ, to the ISOLATED ANALOG
INTERFACE connector, from Pin-22 to Pin-12.

3.

Connect a jumper from Pin-22 to Pin-10.

4.

Program the other parameters to the desired limit values: VOLTAGE PROGRAMMING
INPUT, Pin-9, and the OVP PROGRAMMING INPUT, Pin-3, with respect to Pin-12.

5.

Connect Pin-1, ANALOG-CONTROL, of the ISOLATED ANALOG INTERFACE
connector to Pin-15.