beautypg.com

1 voltage source programming of output voltage, 2 voltage source programming of output current, 3 voltage source programming of ovp – AMETEK DLM 600W Series Programming Manual User Manual

Page 20

background image

Isolated Remote Analog Interface Operation

DLM 600W Series

2-8

M51A Option

2.4.1

Voltage Source Programming of Output Voltage


Setting up for voltage source programming of the output voltage is as follows:

1.

Set Position-1, V, of the INTFC SETUP switch to OFF (down) for 0-5VDC programming
range.


2.

Set Position-1, V, of the INTFC SETUP switch ON (up) for 0-10VDC programming
range.


3.

Connect the external programming voltage source to the ISOLATED ANALOG
INTERFACE connector, with positive to Pin-9 and negative to Pin-12.


4.

Program the other parameters to the desired limit values: CURRENT PROGRAMMING
INPUT, Pin-10, and the OVP PROGRAMMING INPUT, Pin-3, with respect to pin-12.


5.

Connect Pin-1, ANALOG-CONTROL, of the ISOLATED ANALOG INTERFACE
connector to Pin-15.

2.4.2

Voltage Source Programming of Output Current


Setting up for voltage source programming of the output current is as follows:

1.

Set Position-2, I, of the INTFC SETUP switch to OFF (down) for 0-5VDC programming
range.


2.

Set Position-2, I, of the INTFC SETUP switch ON (up) for 0-10VDC programming range.


3.

Connect the external programming voltage source to the ISOLATED ANALOG
INTERFACE connector, with positive to Pin-10 and negative to Pin-12.


4.

Program the other parameters to the desired limit values: VOLTAGE PROGRAMMING
INPUT, Pin-10, and the OVP PROGRAMMING INPUT, Pin-3, with respect to pin-12.


5.

Connect Pin-1, ANALOG-CONTROL, of the ISOLATED ANALOG INTERFACE
connector to Pin-15.

2.4.3 Voltage

Source

Programming of OVP


Setting up for voltage source programming of OVP is as follows:

1.

Set Position-3, OVP, of the INTFC SETUP switch to OFF (down) for 0-5VDC
programming range.

2.

Set Position-3, OVP, of the INTFC SETUP switch ON (up) for 0-10VDC programming
range.


3.

Connect the external programming voltage source to the ISOLATED ANALOG
INTERFACE connector, with positive to Pin-3 and negative to Pin-12.