3 isolated analog interface connector – AMETEK DLM 600W Series Programming Manual User Manual
Page 16
Isolated Remote Analog Interface Operation
DLM 600W Series
2.3 Isolated Analog Interface Connector
The ISOLATED ANALOG INTERFACE connector is a 25-position female
Subminiature-D type.
Pin Function
1 ANALOG-CONTROL
input
2
Return for 0-5/10V monitor outputs and EXTERNAL-OFF
3
OVP programming input
4
Voltage monitor output, 4-20mA
5
VOLTAGE-MODE status output
6
Return for 4-20mA monitor outputs, Auxiliary 5VDC, and digital I/O
7
Current monitor output, 0-5/10V
8
1.25VDC output for 4-20mA voltage programming signal
9
Voltage programming input
10
Current programming input
11
1.25VDC output for 4-20mA current programming signal
12
Return for 0-5/10V or resistance programming signals
13
Return for 4-20mA current programming signal
14 EXTERNAL-OFF
input
15
Auxiliary 5VDC output (+)
16
OVP resistance programming output, 1mA source
17
OVP status output
18
FAULT status output
19
Voltage monitor output, 0-5/10V
20
1.25V input for 4-20mA voltage programming signal
21
Voltage resistance programming output, 1mA source
22
Current resistance programming output, 1mA source
23
1.25V input for 4-20mA current programming signal
24
Current monitor output, 4-20mA
25
Return for 4-20mA voltage programming
Table 2–2. ISOLATED ANALOG INTERFACE Connector Pinout
CAUTION
The signals of the ISOLATED ANALOG INTERFACE have an internal
connection to chassis ground. Damage could result if the voltage from
signal returns, Pin-2, 6, 12, 13, and 25, to chassis ground exceeds
15VDC.
2-4
M51A Option