beautypg.com

3 isolated analog interface connector – AMETEK DLM 600W Series Programming Manual User Manual

Page 16

background image

Isolated Remote Analog Interface Operation

DLM 600W Series

2.3 Isolated Analog Interface Connector

The ISOLATED ANALOG INTERFACE connector is a 25-position female
Subminiature-D type.

Pin Function

1 ANALOG-CONTROL

input

2

Return for 0-5/10V monitor outputs and EXTERNAL-OFF

3

OVP programming input

4

Voltage monitor output, 4-20mA

5

VOLTAGE-MODE status output

6

Return for 4-20mA monitor outputs, Auxiliary 5VDC, and digital I/O

7

Current monitor output, 0-5/10V

8

1.25VDC output for 4-20mA voltage programming signal

9

Voltage programming input

10

Current programming input

11

1.25VDC output for 4-20mA current programming signal

12

Return for 0-5/10V or resistance programming signals

13

Return for 4-20mA current programming signal

14 EXTERNAL-OFF

input

15

Auxiliary 5VDC output (+)

16

OVP resistance programming output, 1mA source

17

OVP status output

18

FAULT status output

19

Voltage monitor output, 0-5/10V

20

1.25V input for 4-20mA voltage programming signal

21

Voltage resistance programming output, 1mA source

22

Current resistance programming output, 1mA source

23

1.25V input for 4-20mA current programming signal

24

Current monitor output, 4-20mA

25

Return for 4-20mA voltage programming

Table 2–2. ISOLATED ANALOG INTERFACE Connector Pinout

CAUTION
The signals of the ISOLATED ANALOG INTERFACE have an internal
connection to chassis ground. Damage could result if the voltage from
signal returns, Pin-2, 6, 12, 13, and 25, to chassis ground exceeds
15VDC.

2-4