beautypg.com

AMETEK ASD Series Quick Start User Manual

Page 3

background image

3

ASD 30kW Quick Reference Guide

– rev X1

© 2011 AMETEK Programmable Power, Inc. All rights reserved.

www.programmablepower.com

PIN

#

PIN NAME

IN/OUT

DESCRIPTION

14

START/STOP_DIN

IN (**)

LO disables output, HI enables output.

15

RESET_DIN

IN (**)

LO to HI transition clears faults and warnings.

16

GND

common

Same as pin 9

17

+24Vdc

OUT

+24VDC, same as pin 10

18-
25

Not used.

Digital signal levels:

(*) Digital output low is 0V (<0.5V), output high is either 12V or 24V (+/-1V), depending on pin 8.

(**) Digital input low is 0.5V or lower, input high is 8V or higher.

Table 2: Analog interface signals. SG-compatible pin-out.

PIN #

PIN NAME

IN/OUT

DESCRIPTION

1

Not used.

2

Not used.

Not used.

4

GND

common

5

ON/OFF

IN

LO = 0 VDC enables output, HI > 10 VDC disables output.

6

GND

common

7

I_MON

OUT

a 0-10 VDC monitor signal (or 4-20 mADC) that indicates zero to full scale
output current.

8

Not used.

9

Not used.

10

Not used.

11

Not used.

12

Not used.

13

Not used.

14

Not used.

15

V_PROG_AIN

IN

a 0-10 VDC analog input signal (or 4-20 mADC) that programs zero to full
scale output voltage.

16

I_PROG_AIN

IN

a 0-10 VDC analog input signal (or 4-20 mADC) that programs zero to full
scale output current.

17

FAULT_DOUT

OUT

LO = 0 VDC indicates normal operation, HI = 12 VDC indicates a fault.

18

Not used.

19

V_MON

OUT

a 0-10 VDC monitor signal (or 4-20 mADC) that indicates zero to full scale
output voltage.

20

Not used.

21

Not used.

22

Not used.

23

GND

common

24

GND

common

25

GND

common

Digital Interface

The connector labeled DIGITAL INTERFACE is an RJ-45 connector that can be either an Ethernet port or an RS-485
half-duplex (2-wire) serial port with industry standard pin-out (pin 4 = RS485-B, pin 5 = RS485-A, pin 7 = 24Vdc, pin 8
= GND, the rest are not used).

The protocol to communicate with the units is MODBUS-TCP with the Ethernet port, or MODBUS-RTU with the serial
port. MODBUS-RTU over Ethernet is also available with the Ethernet port.

If the unit is enabled via the digital interface, it will respond only to the digital interface setpoints and not to the analog
port.