Troubleshooting and Developer Guidelines

UM019206-1011

12

Z8FMC16100 Series Motor Control Development Kit
User Manual

Troubleshooting and Developer
Guidelines

Overview

Before contacting Zilog Customer Support to submit a problem report, please observe the
steps that follow. If there is a hardware failure, contact a local Zilog representative for
assistance.

Recheck Procedures with the Quick Start Guide

Follow the procedures in the

Z8FMC16100 Series Motor Control Development Kit Quick

Start Guide (QS0054)

, and verify that the kit is set up as specified. This quick start guide is

available in the Z8FMC16100 Series Motor Control Development Kit.

IrDA Port Not Working

If you plan on using the IrDA transceiver on the MC MDS Module, ensure that the hard-
ware is set up as follows:

DIS_IRDA jumper J3 must be OUT (shunt not installed) to enable the control gate
that drives the IrDA device

DIS_RS232 jumper J2 must be IN (shunt installed) to disable the console serial port
driver