beautypg.com

TEKVOX TekMonitor 2 User Manual

Page 32

background image

TEK 2

User’s Manual


V111813

32

TEK

VOX, Inc. – 210.348.6565 –

www.tekvox.com

San Antonio, TX 78216

Commands

To help create the Macros and Status commands for the control system a report can be
generated on the Finish page in TekWizard.

Macros

Most commands can be handled by a Macro defined in the TEK 2. To send a Macro command
use the following:

MACRO,# # = 1-

30 Example Macro 1 “MACRO,1”\x0D

Email

EMAIL,# # = 1-5 Normal, 6-10 High Priority and 11-15 Security

Error

ERROR,#,String # = 1-5

Status

Status commands allow for the usage monitoring of selected devices defined in the TEK 2. To
send a Status command use the following:
DSCMD, Index, Value.

Example: Status value 1 on index 0 “DSCMD,0,1”\x0D


MACRO,# # = 1-

30 Example Macro 1 “MACRO,1”\x0D

LOCATION - Returns

“LOC,” and the Location name

BUILDING - Returns

“BUI,” and the Building name

GROUP - Returns

“GRO,” and the Group name

ROOM - Returns

“ROM,” and the Room name

TIME

- Returns

“TIM,” and Time/Data (Hrs),(Min),(Sec),(Month),(Day),(Yr),(WeekDay)

Byte Command

The Byte command is a hardware command that requires a port number, Index and value.
DBCMD, Port, Index, Value

Integer

Integer commands are used to directly set a TEK 2. To send an Integer command use the
following:
DICMD, Port, Value.

Example: Set Volume Left to 50 on Display 2 - “DICMD,3,4”\x0D