Front Panel Features


1. TekSecurity RJ-12 connection. Allows for quick connect of TekSecurity without having to make

wiring connections.

2. Occupancy Sensor connection. Includes the 24 Volt power connection to operate the occupancy

sensor.

3. DO: Digital logic Outputs 2 and 3 - 300 ma at 24 volts. These outputs must share a common

ground with the connected device. PU: 24 volt @ 8 ma (2.7K) pull-up resistor. These resistors
may be required to connect to a Digital Output to provide voltage for the connected device.

4. Logic Inputs 4and 3: Use these inputs for sensing an on or off state of device like a security

connection, a room occupancy detector, a power monitor or a control button.

5. Serial connection Port 2: This connection is a programmable RS-232 data port used to pass data

between the TekMonitor and a connected device.

6. The LAN connection is an auto sensing 10/100 Ethernet connection supporting DHCP, TCP/IP,

UDP, SMTP and Telnet. This port also supports Power-Over-Ethernet.

7. 24 volt connection: Use this power connection to power another device like an occupancy sensor

or power the TEK 2 from another power source, like a power pack for an occupancy sensor.

Link Led (Left)

Activity LED (Right)

Color

Meaning

Color

Meaning

Off

No Link

Off

No Activity

Amber

10 Mbps

Amber

Half-Duplex

Green

100 Mbps

Green

Fill-Duplex



The TEK 2 does not come with an external 24 volt power supply. Power-Over-Ethernet is supported.