Gigabit SFP Hardened Media Converter

12

User’s Manual

Step 1: Connect the DC power cord to the plug-able terminal
block on the media converter, and then plug it into a standard
DC outlet.

Step 2: Disconnect the power cord if you want to shut down the
media converter.

12VDC DC Jack (not supplied; available separately via special
order)

Step 1: Connect the AC to DC power adapter to the receptacle
on the topside of the media converter.

Step 2: Connect the power cord to the AC to DC power adapter
and attach the plug into a standard AC outlet with the
appropriate AC voltage.

Alarms for Power and Port Failure

Step 1: There are two pins on the terminal block that are used
for power failure detection. It provides a normal closed output
when the power source is active. Use this as a dry contact
application to send a signal for power failure detection.



The relay output is normal in an open position when there is no
power to the media converter. Please do not connect any

Power Input Assignment
Power3

12VDC

DC Jack

+ 12-48VDC

Power2

- Power Ground
+ 12-48VDC

Power1

- Power Ground

Earth Ground

Terminal Block

Relay Alarm Assignment

FAULT

*Relay warning signal disable for following:
The relay contact closes if Power1 and
Power2 are both failed but Power3 on.
The relay contact closes if Power3 is failed
but Power1 and Power2 are both on.