Troubleshooting - general, Xml8100 operation – Dual XML8100 User Manual
Page 19
19
XML8100
OPERATION
Problem
Cause
Action
Unit will not turn on
(no power)
Yellow wire not connected or incorrect
voltage Red wire not connected or
incorrect voltage
Check connections for proper
voltage (11~16VDC)
Black wire not connected
Check connection to ground
Fuse blown
Replace fuse
Unit has power
(but no sound)
Speaker wires not connected
Check connections at speakers
One or more speaker wires touching
each other or touching chassis ground
Insulate all bare speaker wires
from each other and chassis
ground
Unit blows fuses
Yellow or red wire touching chassis
ground
Check for pinched wire
Speaker wires touching chassis ground
Check for pinched wire
Incorrect fuse rating
Use fuse with correct rating
Troubleshooting - General