beautypg.com

Appendix a: power consumption, Purpose, Test equipment – NEXCOM APPD 1200T User Manual

Page 65: Device under test, Test procedure, Appd 1200t, Appd 1205t, Appd 1500t, Appd 1700t, Appd 1900t

background image

Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.

50

Appendix A: Power Consumption

APPD 1200T/1205T/1500T/1700T/1900T User Manual

Appendix A: Power Consumption

Purpose

The purpose of the power consumption test is verified the power

dissipation of the system and the load of the power supply.

Test Equipment

PROVA CM-07 AC/DC CLAMP METER
Desktop PC

Device Under Test

DUT: Sys #1

Test Procedure

1. Power up the DUT and then switch on the desktop PC connecting to it.
2. Measure the power consumption and record it.
3. Enter the standby mode (Turn off display).
4. Measure the power consumption and record it.

APPD 1200T

+12V

+24V

Full-Loading Mode

0.73A

0.39A

Total

8.76W

9.36W

Standby Mode

0.05A

0.06A

Total

0.6W

1.44W

APPD 1205T

+12V

+24V

Full-Loading Mode

0.75A

0.39A

Total

9W

9.36W

Standby Mode

0.05A

0.05A

Total

0.6W

1.2W

APPD 1500T

+12V

+24V

Full-Loading Mode

0.97A

0.5A

Total

11.64W

12W

Standby Mode

0.04A

0.05A

Total

0.48W

1.2W

APPD 1700T

+12V

+24V

Full-Loading Mode

2.6A

1.21A

Total

31.2W

29.04W

Standby Mode

0.05A

0.05A

Total

0.6W

1.2W

APPD 1900T

+12V

+24V

Full-Loading Mode

1.54A

0.77A

Total

18.48W

18.48W

Standby Mode

0.05A

0.05A

Total

0.6W

1.2W