beautypg.com

Junger Audio b46 - Digital Audio Leveler User Manual

Page 25

background image

5. OPERATION

Mode menu shows sync setting and input selection.

5.3

MODE MENU

Adjustments are made by pushing and turning CONTROL
knob (see 5.1). Return to level display with EXIT.



SYNC< LINK

AES 1 + 2 3 + 4

SYNC MODE:

selection of sync signal input

CH 1/2

- sync on digital input 1/2

EXT - sync on external sync input

VIDEO

- sync on video sync input

SDI

- sync on SDI input

LINK MODE:

all channels independent or following link

combinations:

1+2, 3+4, 1+2 & 3+4

5.4

INPUT MENU

Input menu shows input setting of the unit. There are two
windows available by pushing INPUT EDIT button once or
twice.
Adjustments are made by pushing and turning CONTROL knob
(see 5.1). Return to level display with EXIT.

1. menu

IN12< TR12 IN34 TR34

AES off SDI on

INxx:

selection of signal input

AES digital input AES/EBU

SDI

SDI input (embedded audio)

TRxx:

selection of transparent input

on/off

for bit transparent path between

auto input and output (for Dolby E)

If set to AUTO the path is switched to
transparent automatically if the
non-audio flag in the AES/EBU or SDI
signal is set.

2. menu (just if SDI interface is present)

SDI GROUPS: > IN< OUT

1

1

IN:

selection of SDI group for deembedding

input signals 1...4

OUT:

selection of SDI group for embedding

output signals 1...4

operation manual b46, chapter 5 -Operation- page 5-3