7/8
PARAMETERS
Connect a clock source with SYNC A IN and an other one with SYNC B IN
The dedicated LOCK A LED turns from red to green to indicate that this input is in use right now and
the C8000 system timing is locked to that source. The LOCK B LED slowly flashes green to indicate
that the input is locked to that reference but it is not in use for the C8000 system clock :
SYSTEM CLOCK
selection of the C8000 system clock
Sample Rate (kHz)
[44.1, 48, 88.2, 96 FOLLOW]
Allow 96kHz
[ON, OFF]
Fallback Sample Rate (kHz)
[44.1, 48, 88.2, 96]
Fallback Video Rate (fps)
[25, 29,97, 30]
Sync Source Priority
Sync A
[ON, OFF]
Sync B
[ON, OFF]
Sync Internal
[ON, OFF]
Fallback on Sync Error
Internal
Video Sync Shift
Video Sync
[-1023 … 0 … 1023]
Shift Offset (lines)