beautypg.com

C8840, C8000, Sync interface – Junger Audio C8840 - Sync interface User Manual

Page 7: Digital audio modular processing system

background image

C8000

sync interface

C8840

digital audio
modular
processing system

7/8


PARAMETERS


Connect a clock source with SYNC A IN and an other one with SYNC B IN
The dedicated LOCK A LED turns from red to green to indicate that this input is in use right now and
the C8000 system timing is locked to that source. The LOCK B LED slowly flashes green to indicate
that the input is locked to that reference but it is not in use for the C8000 system clock :


SYSTEM CLOCK

selection of the C8000 system clock

Sample Rate (kHz)

[44.1, 48, 88.2, 96 FOLLOW]

Allow 96kHz

[ON, OFF]

Fallback Sample Rate (kHz)

[44.1, 48, 88.2, 96]

Fallback Video Rate (fps)

[25, 29,97, 30]


Sync Source Priority

Sync A

[ON, OFF]

Sync B

[ON, OFF]

Sync Internal

[ON, OFF]

Fallback on Sync Error

Internal


Video Sync Shift

Video Sync

[-1023 … 0 … 1023]

Shift Offset (lines)