C8840, C8000, Sync interface – Junger Audio C8840 - Sync interface User Manual
Page 3: Digital audio modular processing system, Installation

C8000
sync interface
C8840
digital audio
modular
processing system
3/8
installation
The C8000 frame must be switched off for installation or swapping of a sync module! Without a stable
clock, some interface modules can fall into irregular condition which could destroy parts of the circuits!
The C8840 must be installed in one of the red coloured fitting rails at rear of a C8932 frame, close to the
mains connector(s).
Setting the CAN address of the module :
ADDRESS
[0, 1, 2, 3]
16 position rotary encoder
A C8000 frame employs the CAN-bus for internal communication
and remote control purposes. For proper operation it is necessary
to assign each module its unique ID. To avoid conflicts, the
address scheme of a C8000 system must be planned with care
(see C8000 System Manual for details).
Since the sync module has a special role in a C8000 frame it
resides in a dedicated address room like the C8702 frame
controller. One may install up to four C8840 modules in a C8934
split (island) frame to support four independent services, each with
Dolby E encoding in a progressive HD format.