background image

digital audio
modular
processing system

C8000

Electrically Isolated GPI/O

C8817

3/8

installation

CAN ADDR

Set the CAN ADDR rotary encoder to an address, which is not in
use by another module of a C8000 frame (for details regarding
CAN addressing, see C8000 system manual).

SW3A

Towards the bottom enables the CAN “+16” address schema to
handle up to 32 modules. If "+16" is turned on, addresses set by
the rotary encoder counting from 0x10 to 0x1F.

SW3B

Not used, must be set towards the bottom.

INIT

Pressing the INIT button during power up will initialize the module
parameters to factory default values.