C8305, C8000, Digital audio modular processing system – Junger Audio C8305 - MADI (BNC) User Manual
Page 7: 64ch bnc madi i/o
digital audio
modular
processing system
C8000
64ch BNC MADI I/O
C8305
phone : +49‐30‐677721‐0
fax :
+49‐30‐677721‐46
info@junger‐audio.com
www.junger‐audio.com
7/11
Jünger Audio‐Studiotechnik GmbH
Justus‐von‐Liebig‐Straße 7
D – 12489 Berlin
GERMANY
SETUP:
Set up of device parameters
Function: MADI Bypass
Off / Active
will bypass the MADI processing
MADI
Input
Auto / Input 1 / Input 2
will allow for automatic switch over from Input 1 to input 2
if Input 1 fails (no signal)
Error Processing Off / Active (used for remote system monitoring)
will turn on the bus error detection in general
Error Mask
S01 to S32
will turn on error detection for individual busses
Important note! You must turn off error detection for busses not in use,
to prevent bad module status.