Sheet17, Drawing view54, Drawing view55 – Future Automation PLH User Manual
Page 16: Drawing view56, Future automation plh, Rs232, Plasma lift hinge mechanism instruction sheet

9
1
2
3
4
5
6
7
8
1
6
pins
PIN 1: IN
PIN 6: OUT
PIN 3&4: GROUND
PIN 2: IN
PIN 3: OUT
PIN 5: GROUND
Sheet 15 of 17
ISSUE: 006
www.futureautomation.co.uk
FUTUREAUTOMATION
PLH
Plasma Lift Hinge Mechanism
Instruction Sheet
RS232
Use an RJ11 connector in the
socket marked RS232 on the
control box to operate using RS232.
DETAILS
Band rate: 9600
Stop bit: 1
Parity: None
Databits: 8
PROTOCOL
ASCI
fa in, = Device IN
fa out, = Device UP and HOME
fa home, = Device UP back to HOME
fa stop, = Device STOP
fa preset, = Device UP and to MEMORY
fa left, = Device UP and to the LEFT
fa right, = Device UP and to the Right