2 temperature protection system (tps) – DynaScan Outdoor 360 Degree LED Video Display DS0706 User Manual
Page 17
Copyright © 2007 DynaScan Technology Corp. 12
4.2 Temperature Protection System (TPS)
DynaScan’s products have a system of temperature protection to implement some
procedures in order to extend their lifetime. If the sensors inside DynaScan’s products
detect the temperature out of the rang from 5℃ to 35℃ when starting, they will take some
actions to protect the products. The following table shows the status and actions for
different protection.
Timing Status
Action
Release
Condition
Start <5℃
Pre-heating(No display, motor still)
>5℃ or
7.5 min later
Start >35℃
Pre-cooling(No display, motor running)
<35℃ or
5 min later
Operating >60℃
Cooling(No display, motor running)
<50℃
Shut
down
--
Cooling(No display, motor running for 6
min)
6 min later