6 how to generate a detailed report, 7 imb configuration script – Doremi ShowVault / IMB User Manual
Page 34

CRT.OM.001420.DRM
Page 34 Version1.6
Doremi Labs
6.6 How to Generate a Detailed Report
If the issue is still not fixed generate a Detailed Report and send it to Doremi Technical Support
(especially BEFORE replacing the current IMB). Along with the Detailed Report, send the
following information: Site name and number, screen number, S/N of the ShowVault, and
projector version.
6.7 IMB Configuration Script
You can execute the script IMB_Configuration_check.sh which will run the commands
outlined in Section 6.5.
The script will be available in /doremi/bin. If
it’s not, please copy it there.
To run the script: Type: > /doremi/bin/IMB_Configuration_check.sh
The script will run multiple commands. You have to press enter to proceed after each
command.
Below are the details of the script as the technician will see it. In case of a failure, the script will
prompt the technician on the steps needs to be taken and it will exit. The technician needs to
follow the script instructions and run the script until it passes all of them.
Checking the IMB is seen on the PCIexpress
IMB was found on the PCIexpress
Continue (y/n)?
y
Checking IMB IP configuration
IMB internal IP is OK
Continue (y/n)?
y
Checking the Projector IP configuration
Inet addr:10.10.1.120 Mask:255.255.255.248
Is this the correct IP addr for the projector (y/n)?
y
Checking the ethernet connection with projector
The projector ethernet is properly connected