Appendix a: unit state string description – CUE relayCUE-8 User Manual
Page 21
Appendix A: Unit State String description
“Unit State String" - current status of all parameters of the unit (lenght 90 bytes):
byte 1
'i'
byte 2 - 5
'0335'
byte 6 - 9
UnitID (BCD)
byte 10-11
FW version
byte 12
STX ("/02")
byte 13-14
input state (HEX)
byte 15-16
output state (HEX)
byte 17-18
internal check state (HEX) 01-O.K.
byte 19-20
unit address (HEX)
byte 21-22
unit bank (HEX)
byte 23-24
long press time in 0.1sec (HEX)
byte 25-26
input filter in 0.01sec (HEX)
byte 27-28
paired relay to relay 1 (HEX) 00-no pair.
byte 29-30
input1 mode (HEX) "0-NoAction", "1-Coded", "2-Relay", "3-SystemOn",
"4-Run", "5-Direction", "6-DelayedOff", "7-DelayedOn", "8-RunDC", "9-Pulse"
byte 31-32
paired relay to relay 2 (HEX) 00-no pair.
byte 33-34
input2 mode (HEX) "0-NoAction", "1-Coded", "2-Relay", "3-SystemOn",
"4-Run", "5-Direction", "6-DelayedOff", "7-DelayedOn", "8-RunDC", "9-Pulse"
...............
byte 55-56
paired relay to relay 8 (HEX) 00-no pair.
byte 57-58
input8 mode (HEX) "0-NoAction", "1-Coded", "2-Relay", "3-SystemOn",
"4-Run", "5-Direction", "6-DelayedOff", "7-DelayedOn", "8-RunDC", "9-Pulse"
byte 59-62
relay1 timer value (HEX)
byte 53-66
relay2 timer value (HEX)
...............
byte 87-90
relay8 timer value (HEX)
Status string example:
"i0335000501\0200000100000504000100010001000100010001000100010005000500050005000500
0500050005"
User Manual relayCUE-8
www.cuesystem.com
Page 21 of 24