6. Addressing

Default address of the rfCUE 99 is 0. That means it transmits BUTTON_ID from 1 to 32. In time of the
delivery the address is set to the default value. Different address setting in time of delivery is
available on request.

The address of the rfCUE 99 can be in set in the range 0 to 9 and can be changed in the rfCUE 99
modify mode - see chapter Modify Mode. When the address is set to 1 the button codes are in range
33 to 64, for address 2 the button codes are in range 65 to 96 and so on.

Generally speaking the button codes of the rfCUE 99 are dependent on the address and can be
calculated according formula

BUTTON_ID

= Offset + Button Code

Offset

= 32 * ADDRESS


The lowest BUTTON_ID is generated by a button in the upper left corner the highest BUTTON_ID is
generated by a button in the lower right corner.

25

26

27

28

30

32

31

29

10

14

2

18

6

22

7

8

20

24

23

19

12

16

11

15

4

3

5

21

17

9

13

1

57

58

59

60

62

64

63

61

42

46

34

50

38

54

39

40

52

56

55

51

44

48

43

47

36

35

37

53

49

41

45

33

313 314 315 316

318

320

319

317

298

302

290

306

294

310

295 296

308

312

311

307

300

304

299

303

292

291

293

309

305

297

301

289

ADDRESS = 1

ADDRESS = 0

ADDRESS = 9