VENTING INSTALLATION
INSTRUCTIONS

Continued

Vertical Termination Configurations

Figures 21 through 24 show four different configurations for verti-
cal termination.

Venting with Two 90

°

Elbows

Vertical (V)

Horizontal (H

1

) +

Horizontal (H

2

)

5' min.

2' max.

6' min.

4' max.

7' min.

6' max.

8' min.

8' max.

20' max.

8' max.

Figure 21 - Vertical Venting Configuration Using Two 90

°

Elbows

with Two Horizontal Runs (Vertical Round High Wind Termination
Shown)

Venting with One 90

°

Elbow

Vertical (V)

Horizontal (H)

5' min.

2' max.

6' min.

4' max.

7' min.

6' max.

8' min.

8' max.

20' max.

8' max.

Figure 22 - Vertical Venting Configuration Using One 90

°

Elbow

(Vertical Round High Wind Termination Shown)

Note: Install restrictor
into inner collar of
fireplace as shown.

Venting with Two 90

°

Elbows

Vertical (V

1

)

Horizontal (H)

5' min.

6' max.

6' min.

12' max.

7' min.

18' max.

8' min.

20' max.

Note: Vertical (V

1

) + Vertical (V

2

) = 40' max.

Figure 23 - Vertical Venting Configuration Using Two 90

°

Elbows

(Vertical Round High Wind Termination Shown)

VENTING INSTALLATION INSTRUCTIONS

Installation for Vertical Termination (Cont.)

Note: Install
restrictor into inner
collar of fireplace
as shown.

45

°

Elbow

Note: Install
restrictor into inner
collar of fireplace
as shown.

45

°

Elbow

45

°

Elbow